Addressable Fire Detectors and Supplies
Beschreibung
Unlike conventinal fire detectors which do not allow precise localisation in case of a fire alarm, addressable detectors can be identified from the central unit by their individually given address and a clear text message indicates the distinct position of the fire. The central unit polls the status of each detector in regular intervals. At the same time it not only recognises detector faults but it receives information about pre-alarms or even the grade of polution of the detector chamber. Like the conventional detectors they have different detection characteristics which have to be considered during the planing of a fire detection system:
Optical Smoke Detectors Intruding smoke activates an alarm in this detector.
It is sensitive to smoke as it arises from smouldering fires even without flames.
UV Flame Detectors Ultraviolet rays as from a flame will actuate an alarm in this detector.
It is suitable for fires with only light smoke emission as from most burning liquids.
Thermal Detectors A thermal detector is sensitive to a certain maximum temperature and/or a rate of rise of temperature.
It is used in enviroments with e.g. steam or dust like in the galley, laundry or sauna.
Multiple Sensor Detectors Detectors like the ACA-E have two or more different sensors like e.g. thermal-optical which enables them to react to different fire characteristics thus detection is more reliable.
Certificate
- EC Certificate Type Examination (Module B) Heat Detectors
- EC Certificate Type Examination (Module B) Wärmemelder
- EC Certificate Type Examination (Module B) Flame Detector
- EC Certificate Type Examination (Mobule B) Handmelder
- EC Certificate Type Examination (Module B) Input / Output Device
- EC Certificate of Conformity Quality System
Module E) QS
Smoke-, Thermal-, Flamdetector, manual call point, monitore
Optical Smoke Detector
ALN-ENM
PDFRate of rise Heat Detector
ATJ-ENM
PDFMulti Detector, Heat- Smok
ACC-ENM
PDFManual Call Point
Manual Call Point
Surface mounting Base
YBN-R3M
PDFShort Circuit Isolator
YBN-R3
PDFSocket recessed mounted
YBN-UA
PDFSocket water tight
MBB-1
PDFDual-Relay Controller
CHQ DRC (SCI)
PDFDual-Switch monitor
CHQ DIM (SCI)
PDFSingle-Zone monitor
CHQ-SZM (SCI)
PDFDual- Zone monitor Ex-I
CHQ-DZM-IS (SCI)
PDFDual-Zone monitor
CHQ-DZM SCI
PDFHousing for CHQ Module
CHQ-Backbox
PDF
Smoke-, thermal und uv/ir detector tester
Smoke detector tester
Solo 330
Thermal detector tester
SOLO 461, 423, 424
Smoke and thermal detector tester
Testifire 1000
UV and IR detector tester
T-229 4P
Safety sheet for smoke detector tester
Solo A3
Smoke detector tester
FDT 533
Safety sheet for smoke detector tester
918/5